SIEMENS CERT
08/09/2022
The products listed below contain two security vulnerabilities in the UMC component that could allow an attacker to cause a partial denial-of-service of the UMC component, or to locally escalate privileges from a user with administrative privileges to execute code with SYSTEM level privileges. Siemens has released updates for several …
SIEMENS CERT
08/09/2022
Multiple vulnerabilities were found in SIMATIC WinCC that ultimately could allow attackers to retrieve and brute force password hashes and access other systems. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures for products …
SIEMENS CERT
08/09/2022
The latest updates for TIA Portal fix a vulnerability that could allow a local attacker to execute arbitrary code with SYSTEM privileges. Update: The previously provided fixes only correctly set the permissions on English Windows versions. Siemens has released updates for several affected products and recommends to update to the …
SIEMENS CERT
08/09/2022
Multiple SIMATIC software products are affected by a vulnerability that could allow an attacker to change the content of certain metafiles and subsequently manipulate parameters or behaviour of devices configured by the affected software products. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
08/09/2022
Siemens Teamcenter Visualization and JT2Go are affected by an out of bounds write vulnerability in APDFL library from Datalogics. If a user is tricked to open a malicious PDF file with the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has …
SIEMENS CERT
08/09/2022
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent . Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
08/09/2022
The below referenced devices contain multiple vulnerabilities that could be exploited when the SINEMA Remote Connect Server (SRCS) VPN feature is used. The feature is not activated by default. The most severe could allow an attacker to execute arbitrary code with elevated privileges under certain circumstances. Siemens has released an …
SIEMENS CERT
08/09/2022
A vulnerability in S7-300 might allow an attacker to cause a Denial-of-Service condition on port 102 of the affected devices by sending specially crafted packets. Siemens recommends specific countermeasures for products where updates are not, or not yet available.