Bulletins

SIEMENS CERT
11/09/2021
Several industrial products as listed below contain a local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
11/09/2021
The networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) use Initial Sequence Numbers for TCP-Sessions that are predictable. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not available.
SIEMENS CERT
11/09/2021
A vulnerability made public under the name SAD DNS affects Domain Name System resolvers due to a vulnerability in the Linux kernel when handling ICMP packets. The Siemens products which are affected are listed below. For more information please see https://www.saddns.net/. Siemens has released updates for several affected products and …
SIEMENS CERT
10/12/2021
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of Profinet Discovery and Configuration Protocol (DCP) reset packets is sent to the affected devices. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
10/12/2021
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
10/12/2021
The latest update for SINEC NMS fixes multiple vulnerabilities. The most severe could allow an authenticated remote attacker to execute arbitrary code on the system, with system privileges, under certain conditions. Siemens has released an update for SINEC NMS and recommends to update to the latest version.
SIEMENS CERT
10/12/2021
The latest update for RUGGEDCOM ROX devices fixes a vulnerability that could allow an unauthenticated attacker to cause a permanent Denial-of-Service condition under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/12/2021
A Denial-of-Service vulnerability found in SINUMERIK Controllers could allow an unauthenticated attacker with network access to the affected devices to cause system failure with total loss of availability. Siemens has released an update for the SINUMERIK 828D and recommends to update to the latest version. Siemens recommends specific countermeasures for …