Bulletins

SIEMENS CERT
08/12/2025
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SIPROTEC, SICAM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., a SICAM device) and a RADIUS server, to forge Access-Request packets in …
SIEMENS CERT
08/12/2025
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
08/12/2025
RUGGEDCOM ROS-based devices are vulnerable to a denial of service attack (Slowloris). By sending partial HTTP requests nonstop, with none completed, the affected web servers will be waiting for the completion of each request, occupying all available HTTP connections. The web server recovers by itself once the attack ends. Siemens …
SIEMENS CERT
08/12/2025
RUGGEDCOM ROS-based devices are vulnerable to a web-based code injection attack. To execute this attack, it is necessary to access the system via the Command Line Interface (CLI). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for …
SIEMENS CERT
08/12/2025
A denial of service vulnerability could allow an unauthorized attacker to cause total loss of availability in the web server of the affected devices. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are …
SIEMENS CERT
08/12/2025
Simcenter Femap contains a file parsing vulnerability that could be triggered when the application reads files in STP or BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or potentially lead to arbitrary code execution. …
SIEMENS CERT
08/12/2025
The basic authentication mechanism of Mendix Runtime contains a race condition vulnerability which could allow unauthenticated remote attackers to circumvent default account lockout measures. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where fixes are …
SIEMENS CERT
08/12/2025
A vulnerability was identified in RUGGEDCOM ROS devices with mirror port enabled, that could allow an attacker to inject information into the network via the mirror port. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products …