SIEMENS CERT
10/11/2022
SIMATIC S7-1200, S7-1500 CPUs and related products protect the built-in global private key in a way that cannot be considered sufficient any longer. The key is used for the legacy protection of confidential configuration data and the legacy PG/PC and HMI communication. This could allow attackers to discover the private …
SIEMENS CERT
10/11/2022
Session fixation and incorrect parameter parsing vulnerabilities were identified in the web server of SICAM P850 and SICAM P855 devices. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/11/2022
JT Open Toolkit (JTTK) and Simcenter Femap are affected by an uninitialized pointer reference vulnerability that could be triggered while parsing JT files. If a user is tricked to open a malicious JT file with any of the affected products, this could cause the application to crash or potentially lead …
SIEMENS CERT
09/13/2022
Intel has published information on vulnerabilities in Intel products in June 2021. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update. In this advisory we summarize: “2021.1 IPU – Intel® CSME, SPS and LMS Advisory” Intel-SA-00459, “2021.1 …
SIEMENS CERT
09/13/2022
A vulnerability in the openSSL component (CVE-2022-0778, [0]) could allow an attacker to create a denial of service condition by providing specially crafted elliptic curve certificates to products that use a vulnerable version of openSSL. Siemens has released updates for several affected products and recommends to update to the latest …
SIEMENS CERT
09/13/2022
SCALANCE devices contain multiple vulnerabilities in MSPS based product lines that could allow authenticated remote attackers to execute custom code or create a XSS situation, as well as unauthenticated remote attackers to create a denial of service condition. Siemens has released updates for several affected products and recommends to update …
SIEMENS CERT
09/13/2022
Simcenter Femap and Parasolid are affected by an out of bounds read vulnerability that could be triggered when the application reads files in NEU format. If a user is tricked to open a malicious file with the affected applications, an attacker could leverage the vulnerability to perform remote code execution …
SIEMENS CERT
09/13/2022
JT2Go and Teamcenter Visualization are affected by multiple file parsing vulnerabilities in Drawings SDK from Open Design Alliance. If a user is tricked to open a malicious DWG file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens …