SIEMENS CERT
01/08/2019
A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
SIEMENS CERT
01/08/2019
Various industrial products use the Discovery Service of the OPC UA protocol stack by the OPC foundation https://github.com/OPCFoundation/UA-.NETStandard and could therefore be affected by the remote resource consumption attacks (CVE-2017-12069).
SIEMENS CERT
01/08/2019
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released …
SIEMENS CERT
12/17/2018
The latest update for TIM 1531 IRC fixes a vulnerability. The devices was missing proper authentication when connecting on port 102/tcp, although configured. An attacker needs to be able to connect to port 102/tcp of an affected device in order to exploit this vulnerability. The vulnerability could allow an attacker …
SIEMENS CERT
12/13/2018
A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
SIEMENS CERT
12/13/2018
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates …
SIEMENS CERT
12/13/2018
TIM 1531 IRC is affected by a vulnerability. The devices are missing proper authentication when connecting on port 102/tcp, although configured. An attacker needs to be able to connect to port 102/tcp of an affected device in order to exploit this vulnerability. The vulnerability could allow an attacker to perform …
SIEMENS CERT
12/13/2018
SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released …