03/12/2020
Products that include the Siemens PROFINET-IO (PNIO) stack in versions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is …
SIEMENS CERT
03/10/2020
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific …
SIEMENS CERT
03/10/2020
S7-300/S7-400 and S7-1200 CPU families are affected by a vulnerability that could allow remote attackers to perform a Denial-of-Service attack by sending a specially crafted HTTP request to the web server of an affected device. Siemens has released updates for several affected products, is working on updates for the remaining …
SIEMENS CERT
03/10/2020
A vulnerability in affected devices could allow an attacker to perform a denial-of-service attack if a large amount of specially crafted UDP packets are sent to the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
03/10/2020
SIMATIC S7-1500 CPU family devices are affected by a vulnerability that could allow an attacker to perform a Denial-of-Service attack if specially crafted UDP packets are sent to the device. Siemens has released updates for the affected products and recommends that customers update to these new versions.
SIEMENS CERT
03/10/2020
Two vulnerabilities have been identified in SIMATIC S7-300 and S7-400 CPU families. One vulnerability could lead to a Denial-of-Service, the other vulnerability could result in credential disclosure. Siemens recommends specific mitigations. Siemens will update this advisory when new information becomes available.
SIEMENS CERT
03/10/2020
SiNVR V3 contains several vulnerabilities in the components Central Control Server (CCS), as well as in the FTP and streaming services of the Video Server. The vulnerabilities involve path traversal (CVE-2019-19290, CVE-2019-19296, CVE-2019-19297), information disclosure (CVE-2019-19291, CVE-2019-19299), SQL injection (CVE-2019-19292), cross-site scripting (CVE-2019-19293, CVE-2019-19294), insufficient logging (CVE-2019-19295), and denial-of-service (CVE-2019-19298). …
SIEMENS CERT
03/10/2020
Two vulnerabilities have been identified in the SIMATIC S7-1200 and S7-1500 CPU families. One vulnerability could allow an attacker with network access to affected devices to modify the user program stored on these devices such that the source code differs from the actual running code. The other vulnerability could allow …