Bulletins

SIEMENS CERT
08/10/2021
SIMATIC CP 1543-1 and CP 1545-1 devices are affected by multiple vulnerabilities in ProFTPD, a third party component, that could allow a remote attacker to access sensitive information and execute arbitrary code. Siemens has released an update for SIMATIC NET CP 1543-1 and recommends to update to the latest version. …
SIEMENS CERT
08/10/2021
One of the DNS-related vulnerabilities that were reported as “Name:Wreck” may affect the following Siemens Energy products: Industrial Gas Turbines SGT-100, SGT-200, SGT-300 and SGT-400 with Allen Bradley control systems Aeroderivative Gas Turbines SGT-A20, SGT-A35 and SGT-A65 with FT125 control systems
SIEMENS CERT
08/10/2021
Siemens has released version V13.2.0.1 for JT2Go and Teamcenter Visualization to fix multiple vulnerabilities that could be triggered when the products read files in different file formats (CGM, DGN, DXF, and DWG). If a user is tricked to open a malicious file with the affected products, this could lead the …
SIEMENS CERT
08/10/2021
Intel has published information on vulnerabilities in Intel products in June 2021. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update. In this advisory we summarize: “2021.1 IPU – Intel® CSME, SPS and LMS Advisory” Intel-SA-00459, “2021.1 …
SIEMENS CERT
08/10/2021
A vulnerability was identified in the Automation License Manager software that could be triggered by sending specially crafted packets to port 4410/tcp of an affected system. This could cause a denial-of-service preventing legitimate users from using the system. Siemens has released an update for the Automation License Manager 6 and …
SIEMENS CERT
08/10/2021
Siemens SCALANCE W1750D is a brand-labeled device. Aruba has released a related security advisory ARUBA-PSA-2021-007 disclosing vulnerabilities in its Aruba Instant product line. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
08/10/2021
SINAMICS medium voltage products, with telnet enabled on SIMATIC comfort HMI Panels, are affected by a remote access vulnerability that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default telnet is disabled, but it can be enabled by the system …
SIEMENS CERT
08/04/2021
Security researchers discovered and disclosed 14 vulnerabilities in the Interniche IP stack, also known as “INFRA:HALT” vulnerabilities [0]. This advisory describes the impact to Siemens low voltage products, which are only affected by four out of the 14 vulnerabilities. Siemens has released updates for the affected products and recommends to …