Bulletins

SIEMENS CERT
05/14/2019
Multiple vulnerabilities have been identified in the WibuKey Digital Rights Management (DRM) solution, which affect SISHIP Automation Solutions. Siemens recommends users to apply the updates to WibuKey Digital Rights Management (DRM) provided by WIBU SYSTEMS AG.
SIEMENS CERT
05/14/2019
Two vulnerabilities have been identified in the SIMATIC S7-400 CPU family that could allow an attacker to cause a Denial-of-Service condition. In order to exploit the vulnerability, an attacker must have access to the affected devices on port 102/tcp via Ethernet, PROFIBUS or Multi Point Interfaces (MPI). Siemens provides updates …
SIEMENS CERT
05/14/2019
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a Denial-of-Service condition on the service or the device. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and …
SIEMENS CERT
05/14/2019
Several industrial controllers are affected by a security vulnerability that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. Precondition for this scenario is a direct OSI Layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released …
SIEMENS CERT
04/09/2019
Security researchers published information on vulnerabilities known as Spectre-NG (Variants 3a and 4). These vulnerabilities affect many modern processors from different vendors to a varying degree. Several Industrial Products include affected processors and are affected by the vulnerabilities.
SIEMENS CERT
04/09/2019
Multiple vulnerabilities affecting WPA/WPA2 implementations were identified by a researcher and publicly disclosed under the term "Key Reinstallation Attacks" (KRACK). These vulnerabilities could potentially allow an attacker within the radio range of the wireless network to decrypt, replay or inject forged network packets into the wireless communication. Several Siemens Industrial …
SIEMENS CERT
04/09/2019
Multiple vulnerabilities have been identified in the WibuKey Digital Rights Management (DRM) solution, which affect WinCC OA. Siemens recommends users to apply the updates to WibuKey Digital Rights Management (DRM) provided by WIBU SYSTEMS AG.
SIEMENS CERT
04/09/2019
SIMOCODE pro V EIP is affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released an update for SIMOCODE pro V EIP and recommends that customers update to the new version.