Bulletins

SIEMENS CERT
01/14/2020
A vulnerability was identified in several SCALANCE X switches that could allow an attacker to feed information into a network via the mirror port with the monitor barrier feature enabled. The monitor barrier implementation in several SCALANCE X switches does allow traffic to be directed back into the mirroring network. …
SIEMENS CERT
01/14/2020
SCALANCE X switches, RUGGEDCOM Win, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released …
SIEMENS CERT
01/14/2020
Two cross-site-scripting (XSS) vulnerabilities were found in the web server of several SCALANCE X switches. Siemens recommends updating the firmware to the newest version as soon as possible.
SIEMENS CERT
01/14/2020
Microsoft has released updates for several versions of Microsoft Windows, which fix a vulnerability in the Remote Desktop Service. The vulnerability could allow an unauthenticated remote attacker to execute arbitrary code on the target system if the system exposes the service to the network. RAPIDPoint® 500 systems operating on Windows …
SIEMENS CERT
01/14/2020
The EN100 Ethernet communication modules are affected by security vulnerabilities which could allow an attacker to disclose information. Siemens has released updates for several affected products, is working on updates for the remaining affected products, and recommends specific countermeasures until fixes are available.
SIEMENS CERT
01/14/2020
The SIPROTEC 5 Ethernet plug-in communication modules and devices are affected by multiple security vulnerabilities. These vulnerabilities could allow an attacker to leverage various attacks, e.g. to execute arbitrary code over the network. The underlying Wind River VxWorks network stack is affected by eleven vulnerabilities known as 'URGENT/11'. Of these, …
SIEMENS CERT
01/14/2020
A vulnerability in SIMATIC WinAC RTX (F) 2010 controller software could allow an attacker to perform a denial-of-service attack if a large HTTP request is sent to the network port of the host where WinAC RTX is running. Siemens has released SIMATIC WinAC RTX (F) 2010 incl. SP3 Update 1 …
SIEMENS CERT
01/14/2020
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific …