Bulletins

SIEMENS CERT
01/08/2019
A Denial-of-Service vulnerability has been identified in SIMATIC PCS 7, SIMATIC WinCC, SIMATIC WinCC Runtime Professional and SIMATIC NET PC-Software. Siemens has released updates for several affected products and recommends that customers update to the new version. Siemens is preparing further updates and recommends specific countermeasures until patches are available.
SIEMENS CERT
01/08/2019
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
01/08/2019
Siemens has released a firmware update for the SIMATIC S7-300 CPU family which fixes a vulnerability that could allow remote attackers to perform a Denial-of-Service attack.
SIEMENS CERT
01/08/2019
SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released …
SIEMENS CERT
01/08/2019
Older versions of the S7-1500 CPU are affected by two Denial-of-Service vulnerabilities. Siemens has released updates for the currently supported hardware versions.
SIEMENS CERT
12/17/2018
The latest update for TIM 1531 IRC fixes a vulnerability. The devices was missing proper authentication when connecting on port 102/tcp, although configured. An attacker needs to be able to connect to port 102/tcp of an affected device in order to exploit this vulnerability. The vulnerability could allow an attacker …
SIEMENS CERT
12/13/2018
SCALANCE X switches, RUGGEDCOM WiMAX, RFID 181-EIP, and SIMATIC RF182C are affected by a vulnerability that could allow an unprivileged attacker located in the same local network segment (OSI Layer 2) to gain system privileges by sending a specially crafted DHCP response to a client's DHCP request. Siemens has released …
SIEMENS CERT
12/13/2018
TIM 1531 IRC is affected by a vulnerability. The devices are missing proper authentication when connecting on port 102/tcp, although configured. An attacker needs to be able to connect to port 102/tcp of an affected device in order to exploit this vulnerability. The vulnerability could allow an attacker to perform …