SIEMENS CERT
05/13/2025
Siemens Teamcenter Visualization contains a out-of-bound read vulnerability that could be triggered when the application reads files in WRL format. If a user is tricked to open a malicious file with any of the affected products, this could lead the application to crash or potentially lead to arbitrary code execution. …
SIEMENS CERT
05/13/2025
Desigo CC deployments that use Installed Client are impacted by an information disclosure vulnerability which could result in information leak from the Desigo CC server. The other Desigo CC client options, Windows App Client and Flex Client, are not affected by this vulnerability. Siemens recommends specific countermeasures for products where …
SIEMENS CERT
05/13/2025
VersiCharge AC Series EV Chargers contain two vulnerabilities that could allow an attacker to gain control of the chargers through default Modbus port or execute arbitrary code by manipulating the M0 firmware. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens …
SIEMENS CERT
05/13/2025
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens has released a new version of Palo Alto Networks Virtual NGFW for RUGGEDCOM APE1808 and recommends to update to the latest version. Customers are advised to …
SIEMENS CERT
05/13/2025
Multiple SICAM products are affected by buffer overflow vulnerability in the IEC 61850 Client libraries from Triangle MicroWorks that could allow an unauthenticated remote attacker to create a denial of service condition by sending specially crafted MMS messages. Affected SICAM and SITIPE products: SICAM A8000 Device firmware ET85 for CP-8000/CP-8021/CP-8022 …
SIEMENS CERT
05/13/2025
Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available. [1] https://security.paloaltonetworks.com/
SIEMENS CERT
05/13/2025
SIMATIC IPC RS-828A is affected by an authentication bypass vulnerability in the Redfish interface of its Baseboard Management Controller (BMC) that could allow an attacker to gain unauthorized access and compromise confidentiality, integrity and availability of the BMC and thus the entire system. Siemens is preparing fix versions and recommends …
SIEMENS CERT
05/13/2025
The latest update for RUGGEDCOM ROS devices fixes a buffer overflow vulnerability in the third party component that could allow an attacker with network access to an affected device to cause a remote code execution condition. Siemens has released updates for the affected products and recommends to update to the …