Bulletins

CISA (ICS)
12/09/2025
1. EXECUTIVE SUMMARY CVSS v3 6.1 ATTENTION : Exploitable remotely/low attack complexity Vendor : Festo SE & Co. KG Equipment : LX Appliance Vulnerability : Cross-site Scripting 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a user of LX Appliance with a high privilege account to craft a …
SIEMENS CERT
12/09/2025
Multiple Siemens products are affected by improper certificate validation in IAM Client. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens is preparing fix versions and recommends countermeasures for products where fixes are not, or not yet available.
SIEMENS CERT
12/09/2025
Affected products do not properly sanitize user-controllable input when parsing files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further …
SIEMENS CERT
12/09/2025
Ruggedcom ROS devices contain a temporary denial of service vulnerability that could allow an attacker to crash and restart the device. Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
12/09/2025
This advisory documents the impact of CVE-2024-3596 (also dubbed “Blastradius”), a vulnerability in the RADIUS protocol, to SCALANCE, RUGGEDCOM and related products. The vulnerability could allow on-path attackers, located between a Network Access Server (the RADIUS client, e.g., SCALANCE or RUGGEDCOM devices) and a RADIUS server (e.g., SINEC INS), to …
SIEMENS CERT
12/09/2025
Energy Services from Siemens (previously known as Managed Applications and Services), sell solutions using Elspec G5 devices that allows a person with physical access to the device to reset the Admin password by inserting a USB drive (containing a publicly documented reset string) into a USB port.
SIEMENS CERT
12/09/2025
Ruggedcom ROX familly contain multiple vulnerabilities before V2.17.0 Siemens has released new versions for the affected products and recommends to update to the latest versions.
SIEMENS CERT
12/09/2025
Multiple Siemens products are affected by improper certificate validation in Siemens Advanced Licensing (SALT) Toolkit. This could allow an unauthenticated remote attacker to perform man in the middle attacks. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for …