SIEMENS CERT
02/08/2022
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a denial of service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has …
SIEMENS CERT
02/08/2022
A vulnerability has been identified in the OPC UA server of several industrial products. The vulnerability could cause a denial of service condition on the service or the device. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates …
SIEMENS CERT
02/08/2022
Intel has published information on vulnerabilities in Intel products in June 2021. This advisory lists the related Siemens Industrial products affected by these vulnerabilities that can be patched by applying the corresponding BIOS update. In this advisory we summarize: “2021.1 IPU – Intel® CSME, SPS and LMS Advisory” Intel-SA-00459, “2021.1 …
SIEMENS CERT
02/08/2022
A vulnerability has been identified in the underlying TCP/IP stack of LOGO! CMR and SIMATIC RTU 3000 devices. It could allow an attacker with network access to the LAN interface of an affected device to hijack an ongoing connection or spoof a new one. The WAN interface, however, is not …
SIEMENS CERT
02/08/2022
Several industrial products are affected by a vulnerability that could allow remote attackers to conduct a Denial-of-Service (DoS) attack by sending specially crafted packets to port 161/udp (SNMP). Siemens has released updates for several affected products, and recommends that customers update to the new version. Siemens is preparing further updates …
SIEMENS CERT
02/08/2022
A vulnerability in the affected products could allow an unauthorized attacker with network access to perform a denial-of-service attack resulting in loss of real-time synchronization. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens is preparing further updates and recommends specific countermeasures …
SIEMENS CERT
02/08/2022
Several SCALANCE X switches are affected by an Authentication Bypass vulnerability. The vulnerability allows an unauthenticated attacker to violate access-control rules. The vulnerability can be exploited by sending a GET request to a specific uniform resource locator on the web configuration interface of the device. The security vulnerability could be …