Bulletins

SIEMENS CERT
11/09/2021
SIMATIC RTLS Locating Manager before V2.12 contains multiple vulnerabilities that could allow an attacker to read sensitive data or trigger a denial-of-service condition of the application service. Siemens has released an update for the SIMATIC RTLS Locating Manager and recommends to update to the latest version.
SIEMENS CERT
11/09/2021
The networking component (Nucleus NET) in Nucleus Real-Time Operating System (RTOS) use Initial Sequence Numbers for TCP-Sessions that are predictable. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends specific countermeasures for products where updates are not available.
SIEMENS CERT
11/09/2021
Siemens NX is affected by two vulnerabilities that could be triggered when the application reads OBJ files. If a user is tricked to open a malicious file with the affected application, this could lead to an access violation, and potentially also to arbitrary code execution on the target host system. …
SIEMENS CERT
10/12/2021
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/12/2021
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
10/12/2021
Twelve vulnerabilities in the implementation of frame aggregation and fragmentation of the 802.11 standard, under the name of FragAttacks, have been published. Successful exploitation of these vulnerabilities could allow an attacker within Wi-Fi range to forge encrypted frames, which could result in sensitive data disclosure and possibly traffic manipulation. The …
SIEMENS CERT
10/12/2021
The latest update for SIPROTEC 5 relays fixes two vulnerabilities that could allow a remote attacker to cause a denial-of-service or potentially trigger a remote code execution under certain circumstances. Siemens has released an update for SIPROTEC 5 relays and recommends to update to the latest version.
SIEMENS CERT
10/12/2021
Products that include the Siemens PROFINET-IO (PNIO) stack in versMions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing …