Bulletins

SIEMENS CERT
10/12/2021
The latest update for RUGGEDCOM ROX devices fixes a vulnerability that could allow an unauthenticated attacker to cause a permanent Denial-of-Service condition under certain conditions. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/12/2021
The Scalance W1750D device contains multiple vulnerabilities that could allow an attacker to inject commands or trigger buffer overflows. Siemens has released updates for the affected products and recommends to update to the latest versions.
SIEMENS CERT
10/12/2021
Products that include the Siemens PROFINET-IO (PNIO) stack in versMions prior V06.00 are potentially affected by a denial-of-service vulnerability when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. Siemens has released updates for several affected products and recommends to update to the new versions. Siemens is preparing …
SIEMENS CERT
10/12/2021
The latest update for SIPROTEC 5 relays fixes two vulnerabilities that could allow a remote attacker to cause a denial-of-service or potentially trigger a remote code execution under certain circumstances. Siemens has released an update for SIPROTEC 5 relays and recommends to update to the latest version.
SIEMENS CERT
10/12/2021
Twelve vulnerabilities in the implementation of frame aggregation and fragmentation of the 802.11 standard, under the name of FragAttacks, have been published. Successful exploitation of these vulnerabilities could allow an attacker within Wi-Fi range to forge encrypted frames, which could result in sensitive data disclosure and possibly traffic manipulation. The …
SIEMENS CERT
10/12/2021
A Denial-of-Service vulnerability found in SINUMERIK Controllers could allow an unauthenticated attacker with network access to the affected devices to cause system failure with total loss of availability. Siemens has released an update for the SINUMERIK 828D and recommends to update to the latest version. Siemens recommends specific countermeasures for …
SIEMENS CERT
10/12/2021
Several industrial devices are affected by two vulnerabilities that could allow an attacker to cause a Denial-of-Service condition via PROFINET DCP network packets under certain circumstances. The precondition for this scenario is a direct layer 2 access to the affected products. PROFIBUS interfaces are not affected. Siemens has released updates …
SIEMENS CERT
09/28/2021
Siemens has released a new version for Solid Edge that fixes multiple file parsing vulnerabilities which could be triggered when the application reads files in IFC, JT or OBJ formats. If a user is tricked to opening a malicious file using the affected application this could lead the application to …