Bulletins

SIEMENS CERT
01/12/2021
The products listed below contain a vulnerability that could allow remote attackers to affect the availability of the devices under certain conditions. The underlying TCP stack can be forced to make very computation expensive calls for every incoming packet which can lead to a Denial-of-Service. Siemens is working on software …
SIEMENS CERT
01/12/2021
SIMOTICS CONNECT 400, Desigo (Power PC-based), APOGEE MEC/MBC/PXC and TALON TC products are affected by a DHCP Client vulnerability as initially reported in SSA-434032 for the Mentor Nucleus Networking Module. Siemens has released updates for several affected products and recommends to update to the latest versions. Siemens recommends countermeasures for …
SIEMENS CERT
01/12/2021
The latest update for affected products fix local privilege escalation vulnerabilities that could allow authorized local users with administrative privileges to execute custom code with SYSTEM level privileges. Siemens has released updates for some of the affected products, and is working on further updates. For the remaining affected products, Siemens …
SIEMENS CERT
12/08/2020
Multiple SIMATIC Software products are affected by two vulnerabilities that could allow an attacker to manipulate project files that may lead to Remote Code Execution or Denial-of-Service attacks. Siemens has released updates to some of the affected products and recommends that customers update to the latest version. Siemens is preparing …
SIEMENS CERT
12/08/2020
The latest update for LOGO! 8 BM fixes multiple vulnerabilities. The most severe could allow an attacker with network access to gain full control over the device. Siemens has released updates for the affected products and recommends that customers update to the latest version.
SIEMENS CERT
12/08/2020
Recently security researchers discovered and disclosed 33 vulnerabilities in several open-source TCP/IP stacks for embedded devices, also known as “AMNESIA:33” vulnerabilities. The Siemens products mentioned below are affected by one of these vulnerabilities (CVE-2020-13988). Siemens has released updates for SENTRON PAC devices, is working on updates for SIRIUS 3RW5 communication …
SIEMENS CERT
12/08/2020
SIMATIC ET 200SP Open Controller V20.8 and SIMATIC S7-1500 Software Controller V20.8 are affected by a denial-of-service vulnerability in the web server. Siemens has released updates for the affected products and recommends to update to the latest version.
SIEMENS CERT
12/08/2020
Multiple vulnerabilities have been identified in the XHQ Operations Intelligence product line. These vulnerabilities could allow for data injection in the XHQ’s web interfaces. Siemens recommends to update XHQ Operations Intelligence product line to the newest version.