Bulletins

CISA (ICS)
08/14/2025
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). 1. EXECUTIVE SUMMARY CVSS v3 …
BOSCH PSIRT
08/14/2025

BOSCH-SA-757244: Several fieldbus couplers sold by Bosch Rexroth contain technology from Phoenix Contact. The manufacturer published a security bulletin about a weakness in the web-based administration interface. A successful attack leads to an overload of the device and the hardware watchdog is triggered. Process data behaves according to the configured …

BOSCH PSIRT
08/14/2025

BOSCH-SA-129652: Vulnerabilities in ctrlX OS - Setup

SIEMENS CERT
08/14/2025
Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version.
SIEMENS CERT
08/14/2025
Versions V5.0 through V8 of the Desigo CC product family (Desigo CC, Desigo CC Compact, Desigo CC Connect, Cerberus DMS), as well as the Desigo CC-based SENTRON Powermanager, are affected by a vulnerability in the underlying third-party component WIBU Systems CodeMeter Runtime. Successful exploitation of this vulnerability could allow privilege …
SIEMENS CERT
08/13/2025
Siemens BFCClient contains multiple vulnerabilities in the integrated OpenSSL component that could allow an attacker to read memory contents, to change the application behaviour or to create a denial of service condition. Siemens has released a new version for BFCClient and recommends to update to the latest version.
SIEMENS CERT
08/12/2025
Affected products do not properly sanitize user-controllable input when parsing project files. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing …
SIEMENS CERT
08/12/2025
Affected products do not properly restrict access permissions to a local Windows Named Pipe and do not properly sanitize user-controllable input sent to that Named Pipe. This could allow a local authenticated attacker to cause a type confusion and execute arbitrary code within the affected application and its privileges. Siemens …