Bulletins

SIEMENS CERT
08/10/2021
Intel has published information on vulnerabilities in Intel products in November 2020. This advisory lists the Siemens IPC related products, that are affected by these vulnerabilities. In this advisory we take a representative CVE from each advisory: “Intel CSME, SPS, TXE, AMT and DAL Advisory” Intel-SA-00391 is represented by CVE-2020-8745 …
SIEMENS CERT
08/10/2021
Siemens SCALANCE W1750D is a brand-labeled device. Aruba has released a related security advisory ARUBA-PSA-2021-007 disclosing vulnerabilities in its Aruba Instant product line. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet available.
SIEMENS CERT
08/10/2021
SINAMICS medium voltage products, with telnet enabled on SIMATIC comfort HMI Panels, are affected by a remote access vulnerability that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default telnet is disabled, but it can be enabled by the system …
SIEMENS CERT
08/10/2021
OpenSSL has published a security advisory [0] about a vulnerability in OpenSSL versions 1.1.1 < 1.1.1k, that allows an unauthenticated attacker to cause a Denial-of-Service (DoS) if a maliciously crafted renegotiation message is sent. Siemens is preparing updates and recommends countermeasures for products where updates are not, or not yet …
SIEMENS CERT
08/10/2021
The Video Server application in SiNVR/SiVMS solutions contains five vulnerabilities involving information disclosure (CVE-2019-19291, CVE-2019-19299), path traversal (CVE-2019-19296, CVE-2019-19297), and denial-of-service (CVE-2019-19298). PKE has released updates of the application that fixes the reported vulnerabilities, except for CVE-2019-19299. This update is not available under the former Siemens OEM brand name SiNVR. …
SIEMENS CERT
08/10/2021
SINAMICS medium voltage products, with Sm@rtServer enabled on SIMATIC comfort HMI Panels, are affected by multiple vulnerabilities that could allow an attacker, under certain conditions, to gain full remote access to the HMI. Note that by default Sm@rtServer is disabled, but it can be enabled by the system integrator on …
SIEMENS CERT
08/04/2021
Security researchers discovered and disclosed 14 vulnerabilities in the Interniche IP stack, also known as “INFRA:HALT” vulnerabilities [0]. This advisory describes the impact to Siemens low voltage products, which are only affected by four out of the 14 vulnerabilities. Siemens has released updates for the affected products and recommends to …
SIEMENS CERT
07/13/2021
The latest update for the below listed products fixes two security vulnerabilities that could allow an attacker to cause a partial Denial-of-Service on the UMC component of the affected devices under certain circumstances, and one vulnerability that could allow an attacker to locally escalate privileges from a user with administrative …